Trigger:
A) Openable windows in bedrooms: The below rules apply when building openable windows or louvres "where the floor below the window is 2 m or more above the surface beneath" AND "where the lowest level of the window opening is less than 1.7m above the floor" AND where the window is located in a bedroom.
In practical terms, this includes second storey openable bedroom windows or louvres, the bottom of which is less than 1.7m from the second storey floor level.
B) Openable windows not in bedrooms: The below rules apply when building openable windows or louvres "where the floor below the window is 4m or more above the surface beneath" AND where the window is not located in a bedroom.
Rule:
A) Openable windows in bedrooms: Where an openable window meets the trigger at A, there are two options:
1) a non-removable device or screen that does not allow a 125mm sphere to pass through the window or louvres. One solution would be, for example, a screen riveted into the window frame that cannot easily be removed without a drill.
2) a child resistant device or screen that does not allow a 125mm sphere to pass through, plus a window sill barrier at least 865mm from the floor level. One solution would be, for example, a short chain winder on the window frame with a window sill.
B) Openable windows not in bedrooms: Where an openable window meets trigger B, we must install a window sill barrier at least 865mm from the ground.
Reference: The relevant rules are found in the National Construction Code Volume 2 at 3.9.2.6 and 3.9.2.7.
QAID 748 · last reviewed 21 November 2026