Questions & Answers › Approvals and planning rules
What does the fire rating FRL 60/60/60 mean?
FRL = Fire Resistance Level. The 60 represents minutes. The three numbers represent “Structural adequacy/ Integrity / Insulation”. This means that if a building element were exposed to a standard fire test, it would not be expected to fail for 60 minutes in each of the three criteria. The BCA specifies FRLs for building elements such as walls, columns, roofs and floors.
QAID 596 · last reviewed 21 November 2026