On upper floors, the 6m side and rear setback applies to "unscreened elements", which the Territory Plan defines as unscreened windows, decks, balconies and external stairs. An upper floor window within 6m of the boundary therefore complies if it's screened. A screened window then only needs to meet the external wall setback, which is generally 3m in the primary building zone. The acceptable ways to screen it come from the Territory Plan's definition of a screening device, which is a permanent structure using one or more of the following:
- Opaque or translucent glazing: for example, fixed frosted or obscure glass.
- Solid panels: fixed panels in front of the window.
- Perforated panels or trellises: with no more than 25% openings.
- Angled louvres: fixed so they restrict overlooking of the neighbouring property.
The screening must be permanent, so blinds, curtains or adjustable fittings that can be opened don't count. High-sill or highlight windows are commonly used to avoid overlooking. However, the definition doesn't expressly list them, so confirm with the certifier that a particular sill height is acceptable. Other options are to set the unscreened window back at least 6m, reorient it to face the street or the owner's own land, or seek an exemption declaration for a minor departure. For an exemption declaration, ACT Planning strongly recommends getting the neighbour's written support for unscreened setback departures. Anything beyond that requires a DA, where privacy impacts are assessed on merit.
Sources: Territory Plan 2023, Part G Dictionary (definitions of screening device and unscreened element); Single Dwelling Housing Development Control Declaration 2025 (No 2), Tables 4–7, as uploaded.