Does the entire length of the wall need to be fire rated?
Only the area of a wall that breaches the fire rating criteria (ie: 900mm boundary or Class10a and 1800mm Class1 to Class1). For example, if the entire length of a wall is within 900mm of a boundary fence, say 850mm, in this case, the entire wall needs to be FRL 60/60/60 in the ACT. However, if a corner of the building is within 1800mm of another Class 1 structure, say 1600mm), then only the area of the structure that is breaching the 1800mm distance needs to be FRL 60/60/60.
A class 1 structure only needs to be fire rated for the length of the class 10a structure it is less than 900mm from. See below diagram