Questions & Answers › Before we start on site
Can you explain why instantaneous gas is viable, but electric is not? Given than gas will still face the same issues with the colder Canberra waters
Gas faces the same cold incoming water as electric. Either type has to supply the same amount of energy. The difference is where that energy comes from. Electric is limited by how much power we can safely draw and the limits placed on residential supply. Gas is not limited in the same way.
We set the performance standard for a typical household. We need to anticipate two showers running at the same time.
Typical water-saving showerheads use 9L per minute. So two showers will use 18L per minute, or 1,080 litres per hour. For a comfortable hot shower, the recommended temperature is 38°C to 40°C. According to the reservoir reports, the cold temperature is 7.5°C, so we need to heat the water by at least 30.5°C.
The energy required to heat water is determined by the specific heat capacity of water, which is 4.186 J/g°C. This means it requires 4.186 J of energy to heat a gram of water by one degree. So we need to heat 1,080L of water by 30.5 degrees. This means we need 1.38E+08 joules every hour, or 138MJ/hr. To supply this amount of energy, assuming 95% efficiency, we will need an electric system of 40.3kW.
This is a very large amount of power for residential use. The maximum size for most residential units, even with three-phase, is 27kW. In the spec sheets of a three-phase heating unit, the 18kW unit is barely able to provide enough hot water for one shower, and the 27kW unit is not enough for two showers at the same time in cold weather. Two showers at once would need two three-phase heating units.
Electric instantaneous is not impossible. An instantaneous electric system with no storage over 80L is a compliant type. But to handle Canberra's cold water, we would need significant electrical upgrades to the existing consumer mains and power service cables, and a dedicated circuit wired directly to the hot water service. This is a large upfront investment, anywhere from $4,000 to $14,000 depending on the existing infrastructure. For this reason we do not recommend it as the main system.
Gas, while less efficient, does not have this limit as it is a very energy-dense product. Each kg of gas provides 20MJ of energy. Most gas systems are rated for 20+ litres per minute for a 30 degree rise.
QAID 788 · last reviewed 22 November 2026
Related questions
- How are new connections made to a new building from an existing building? These connections include sewer, electricity, gas, water, storm water
- At what stage during the build will the power, water, gas and sewer facilities be functional?
- What is the process if we need to get our power lines that connects energy to our house moved because of the proposed development?
- When there’s a powerline shown on the proposal, is it provided to show that it can’t be built on?